Delphi Force Measurement Pty Ltd

Made in Australia






Low Profile Load Cell

Custom Designs and Variations

Stainless steel low profile load cells are used where height is restricted and/or eccentric or side loads are encountered. Can be used without tie rods or stays. Place under machinery or structures to record weight/force. Can be used indoors or outdoors.

All cells are fitted with IP68 Mil Spec equivalent plug and socket.

Low profile cell Low profile cell

Tonnes A B C D E F G
2.5, 5, 10351063228M 20990
25 & 50561405050M 2411116
50 & 100802257562M 3617190
250155320140145M 10016 @ 21270


Low Profile Load Cell Specifications

Capacities 2.5, 5, 10, 25, 50, 100, 250
Overload 150% no effect; 400% ultimate
Excitation 20v. DC max
Rated output 2 mV / V nominal
Zero balance + / - 1%
Non-linearity 0.05%
Non-repeatability 0.02%
Hysteresis 0.02%
Creep 0.03%
Temperature Effects
On zero
On span
Range: -10 to 80 *c
0.003% / *c
00.003% / *c
Bridge resistance 700 Ω nominal
Connection: Mil spec plug. Optional: Cable or conduit gland


Delphi-Force Measurement Pty Ltd
64 Township Drive, West Burleigh
Gold Coast Qld 4219
Email: sales@delphi-force.com
Phone: 61-7-5508 2498
Fax: 61-7-5508 2650
24 month warranty

Made in Australia